lisaann在线观看-销魂老女人老泬-久久久久久久久久久激情-国内日韩免费在线一级片

Your Position: Home > Support > FAQ

Oil Shortage Phenomenon and Replacement of Vacuum Oil Filter Oil Products

2019/8/1??????view:

  1. Check oil

  The oil level of the pump in operation must be located in the middle of the oil level glass window (6/4). If necessary, stop the pump and refuel according to the correct amount of oil. Excessive oil filling causes oil loss at high suction pressure.

  High fuel consumption generally indicates that the exhaust filter is blocked.

  When filling oil into the pump, the pump must be stopped.

  Check oil level at least once a day.

  2. Oil state

  Generally speaking, oil is clear and transparent. If the oil is dark, it should be replaced.

  If gases or liquids are dissolved in the oil, the limit pressure will deteriorate. Closing the inlet and opening the ballast valve to make the pump run for about 30 minutes can degasse the oil.

  When the pump is still at working temperature after stopping, some oil is discharged into beakers or similar containers through the discharging screw (6/5), which can be used to check the state of oil.

  warning

  According to the process involved, hazardous substances can spill over from pumps and oils. Corresponding safety measures should be taken.

  Comply with safety regulations.

  3. Change oil, change oil filter

  Tools used:

  Oil filter wrench (710 73 532)

  Always change oil when the pump is still at working temperature after shutdown.

  If the oil is in danger of polymerization of process gases in contact with it, the oil should be changed immediately after the pump is running.

  warning

  Pumps are hot in operation. Some surfaces can be as high as 80 (176).

  There is a risk of scald if touched.

  Turn off the drain plug (6/5) and let the used oil drain into the proper container.

  warning

  According to the process involved, hazardous substances can spill out of the pump or pump oil. Corresponding measures should be taken.

  Comply with safety regulations.

  Important Notes

  When handling used oil, please observe the relevant environmental regulations!

  When discharging oil, when the flow of oil decreases, screw the discharging screw on, start the pump for a short time (up to 10 seconds), and then stop the pump. Then screw down the oil drain plug to drain the remaining oil.

  Remove the oil filter (6/25), take a new oil filter, soak it with oil, and screw it on by hand.

  Re-install the drain plug (check the "O" ring and replace it with a new one if necessary).

  Remove the filling screw plug (6/6) and inject new oil into the lower edge of the oil level window, so that the pump can run for a short time, so as to flush the pump with the filling new oil. Then let the oil go.

  Use only the appropriate oil (see Section 1.8).

  warning

  According to the process involved, hazardous substances can spill over from pumps and oils. Corresponding measures should be taken. Comply with safety regulations.

  Watch out

  Do not install used seals; be sure to install new seals.

  Important Notes

  When handling used oil, please observe the relevant environmental regulations!


拜城县| 东乡县| 年辖:市辖区| 泾源县| 乐平市| 石屏县| 石嘴山市| 麻栗坡县| 陆河县| 黄浦区| 纳雍县| 东方市| 县级市| 浙江省| 镇坪县| 垦利县| 丰县| 鹰潭市| 中宁县| 双辽市| 万年县| 白银市| 芜湖市| 永福县| 社会| 南开区| 东乡| 华坪县| 工布江达县| 县级市| 桃源县| 溆浦县| 云和县| 临西县| 多伦县| 罗甸县| 嘉祥县| 卢湾区| 青神县| 清徐县| 拉萨市|